Ibm Modbus Plus Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Ibm Modbus Plus. IBM Modbus Plus User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Modbus Plus
X-Link Driver
User’s Guide
Version 1.22
50 Northland Road
Waterloo, Ontario, CANADA
N2V 1N3
Tel: (519) 725-5136 Fax: (519) 725-1515
www.sstech.on.ca
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - User’s Guide

Modbus PlusX-Link DriverUser’s GuideVersion 1.22 50 Northland Road Waterloo, Ontario, CANADA N2V 1N3 Tel: (519) 725-5136 Fax: (5

Page 2

Modbus Plus X-Link Driver User’s Guide442.1 RequirementsTo communicate to the Modbus Plus network, the X-Link requires aModicon SA85 card. The X-L

Page 3 - Contents

Configuration453ConfigurationWhen you download a driver to the X-Link, you must set configurationparameters to control the interface between the drive

Page 4

Modbus Plus X-Link Driver User’s Guide463.1 Configuration ParametersThe Modbus Plus driver is distributed in the file SA85.DRV. Once theSA85.DRV i

Page 5 - Introduction

Mappings474MappingsOnce the X-Link has been loaded, you can create mappings to transfer datafrom one network to the other. This section outlines the m

Page 6

Modbus Plus X-Link Driver User’s Guide484.1 Data Types and LengthsThe Modbus Plus Driver supports three X-Link data formats; Bits andIntegers, as

Page 7 - 1.3 How Do I Use This Manual?

Mappings494.2 Source AccessesThe Modbus Plus driver supports four possible source accesses.The first source defines a local address which allows any d

Page 8

Modbus Plus X-Link Driver User’s Guide504.3 Destination AccessesThe Modbus Plus driver supports three possible destination accesses.The first dest

Page 9 - Communication

Mappings514.4 Local AddressesWhen a mapping is created which allows a PLC to access data within theX-Link, a local address dialog box must be complete

Page 10 - 2.2 Compatibilities

Modbus Plus X-Link Driver User’s Guide524.6 Status CountersThe status counters are maintained within the Modbus Plus driver forlogging events and

Page 11 - Configuration

Troubleshooting535TroubleshootingIf you cannot communicate with your X-Link, refer to the troubleshootingsection in the X-Link User's Guide. If y

Page 12 - 3.1 Configuration Parameters

Modbus Plus X-Link Driver User’s Guide36Publication Revision: 1.22Publication Date: January 15, 1999This document applies to the Modbus Plus X-Lin

Page 13 - Mappings

Modbus Plus X-Link Driver User’s Guide54

Page 14 - 4.1 Data Types and Lengths

Specification556Specification6.1 Driver CMOS Storage RequirementsDriver Code and Parameters 16 KbytesEach Global Data Read Address 4 bytesEach Globa

Page 15 - 4.2 Source Accesses

Modbus Plus X-Link Driver User’s Guide56

Page 16 - 4.3 Destination Accesses

Modbus Plus X-Link Driver User’s Guide37Contents1. Introduction...391.1 What is the Modbus Pl

Page 17 - 4.5 External Addresses

Modbus Plus X-Link Driver User’s Guide38

Page 18 - 4.6 Status Counters

Introduction391Introduction1.1 What is the Modbus Plus Driver?The Modicon Modbus Plus X-Link driver allows the X-Link to transfer datato or from devic

Page 19 - Troubleshooting

Modbus Plus X-Link Driver User’s Guide401.2 Why Do I Need This Manual?This manual describes the communication requirements and capabilities ofthe

Page 20

Introduction411.3 How Do I Use This Manual?The following conventions will help you better understand and use thematerial in this manual.Text you type

Page 21 - Specification

Modbus Plus X-Link Driver User’s Guide421.4 Where Can I Find More Help?If you have a question or problem that the manuals or on-line help do notad

Page 22

Communication432CommunicationOnce configured, the X-Link emulates a station on the Modbus Plusnetwork. It can send messages to other stations and rece

Commentaires sur ces manuels

Pas de commentaire