Examples
The following are examples of ways you can use the Display System Environmental
Sensors service aid.
1. Display a list of the environmental sensors:
/usr/lpp/diagnostics/bin/uesensor -l
Sensor = Fan Speed
Status = Normal
Value = 2436 RPM
Location Code = F1
Sensor = Power Supply
Status = Normal
Value = Present and operational
Location Code = V1
Sensor = Power Supply
*Status = Critical low
Value = Present and not operational
Location Code = V2
2. Display a list of the environmental sensors in a numerical list:
/usr/lpp/diagnostics/bin/uesensor -a
3 0 11 87 P1
9001 0 11 2345 F1
9004 0 11 2 V1
9004 1 9 2 V2
3. Return the status of sensor 9004, index 1:
/usr/lpp/diagnostics/bin/uesensor -t 94 -i 1
9
4. Return the value of sensor 9004, index 1:
/usr/lpp/diagnostics/bin/uesensor -t 94 -i 1 -v
2